Cartridge & Rotor
Feed Solution
Comparison technology
• Colton & Smith (1972): Sh = 0.285 × Re0.567 × Sc0.33
• Koutsou & Karabelas (2012): Stirrer diameter 21 mm, geometry & assumptions; mean wall shear stress 〈τ〉 = 0.85 Re0.49 μω (Eq. 7), Re = ρωR²/μ, R = 16.5 mm
CP factor Γ vs Jv
Log scale 0.01–100. Nine reference membrane classes (SWRO → open UF), toggle below. Green band: reliable window (Γ < 0.20). Dots: operating point at the specified ΔP.
Solute passage (1−R) vs Jv
Solid line: Rint(Jv) = Jv/(Jv+B). At the operating ΔP, each class operates at a different Jv: open circle = Rint, filled = Robs. The gap between them shows the CP correction — larger for classes that require lower RPM.
Model: Geraldes V., Fan H., Yang M., Rodrigues M., Elimelech M. — "Predicting concentration polarization in Ortho-Centrifugal Membrane Filters for NF/RO membrane screening." Preprint under review, Journal of Membrane Science (2026). Thermo-physical properties at 20 °C from Table 1 of the same work (PEG 35 kDa: Table A.1, data of Pires et al.). Correlation kc/U* = 0.261 𝒢1/4 Sc−1/4, with the finite-permeation closure Ξ(φ) of Geraldes & Afonso (2006), Γ = Rint φX / (1 + (1 − Rint) φX), X = (1 + 0.26 φ1.4)1.7, exact in Rint — used for every solute and device, since film theory (valid only for φ ≲ 1.5) is a special case of it. In the O-CMF, ν and D are evaluated at the film concentration ½(cm + c0). In the stirred cell and the spiral-wound module (forced convection) the correlations keep the bulk properties and kc is multiplied by the weak viscosity correction (νm/ν0)−0.075 found in the reconstructed radial cross-flow cell (36 runs); evaluating a Re0.875Sc0.25 law at the film concentration would over-correct. Validated against DNS for Sc ∈ [700, 2200] and 𝒢 ∈ [7×10⁻⁹, 5×10⁻⁶] (mean relative deviation ~7%, maximum ~22%), and against twelve reconstructed PEG 35 kDa ultrafiltration experiments in the O-CMF (Pereira, MSc thesis, IST 2026; Sc ≈ 3×10⁴, Γ 2–66, φ 1.4–7, within ±20 % in Γ). Membrane classes are indicative permeabilities; B defaults to the value backed out of the PEG reconstructions (Rint ≈ 0.96–0.996) for that solute, and to Table 1 values for the others.